Test Method
IHC
CPT Code
88313
Stains / Test Description
Special stain. The combination of the alcian blue and the PAS techniques can be used as a means of distinguishing neutral mucins from acid mucins. In most protocols, sections are stained with the standard alcian blue (pH 2.5) method followed by the PAS technique. The combined application of alcian blue and PAS is useful for several reasons, including changes in the distribution or pattern of expression of neutral and acid mucins that are indicative of certain pathological conditions
Specimen Requirements
(1) H&E slide with formalin-fixed, paraffin-embedded (FFPE) tissue, fixed with 10% NBF.
or
One (1) unbaked, unstained slide for H&E staining (required) and two to three (2-3) positively charged unstained slides (all cut at 4 microns) for each test/antibody ordered
Block and slide identifiers should be clearly written and match exactly with the specimen ID and specimen labeling as noted on the requisition.
or
One (1) unbaked, unstained slide for H&E staining (required) and two to three (2-3) positively charged unstained slides (all cut at 4 microns) for each test/antibody ordered
Block and slide identifiers should be clearly written and match exactly with the specimen ID and specimen labeling as noted on the requisition.
Storage & Transport
Ship specimen same day (whenever possible) with refrigerated (not frozen) cold pack
Turnaround time
1-3 days depending on level of service
Level of Service
Global (with interpretation)
Slide Only (glass slides only)
Web-Enabled (glass and digital images through eCSI portal)
Slide Only (glass slides only)
Web-Enabled (glass and digital images through eCSI portal)